Memories BRAM80KFIFO
Speedster22i Macro Cell Library
AchronixSemiconductorProprietary PAGE 121
Parameters
Table 6-16: BRAM80KFIFO Parameters
Parameter Defined Values Default Value
sync_mode 1’b0
write_width 40
read_width 40
fwft 1’b0
en_out_reg 1’b1
reg_initval 40’h0
reg_srval 40’h0
reg_rstval 1’b1
regce_priority “rstreg”
wrrst_rstval 1’b1
wrrst_input_mode 2’b10
wrrst_sync_stages 2’b00
wrptr_sync_stages 2’b00
rdrst_rstval 1’b1
rdrst_input_mode 2’b10
rdrst_sync_stages 2’b00
rdptr_sync_stages 2’b00
wrcount_sync_mode 1’b1
rdcount_sync_mode 1’b1
afull_offset 17’h00004
aempty_offset 17’h00004
wren_polarity_sel 1’b1
rden_polarity_sel 1’b1
en_rd_when_empty 1’b0
en_wr_when_full 1’b0
sync_mode
The sync_mode parameter is used to bypass the synchronization circutry between the read
andwriteportswhenbothportsareconnectedtothesameclock.Ifboththewrclkandrdclk
clockinputsareconnectedtothesameclockwithoutanyphasedifferencebetweentherdclk
andwrclkinputs,theusermaysetthesync_m
odeparameterto1’b1toallowfasterupdatesto
thestatusflags(empty,full,etc.).Ifthereadandwriteclocksareconnectedtodifferentclocks,
thesynchronizationcircutrymustbeusedandthesync_modeparametermustbesetto1’b0.
Thedefaultvalueofthesync_modeparameteris1’
b0.
write_width
Thewrite_widthparameterdefinesthe widthof thedatainputbusoftheFIFO fromone to
fortybitsaccordingtotheallowedvaluesdefinedinTable616
: BRAM80KFIFOParameters.
Table617
: FIFOwrite_widthversusMaximumWriteDepthdefinesthemaximumdepthof
theFIFO foreachoftheva
lid valuesof thewrite_widthparameter. Thedefault value ofthe
write_widthparameteris40’h0.
1’b0, 1’b1
1, 2, 4, 5, 8, 9, 10, 16, 18, 20, 32, 36, 40
1, 2, 4, 5, 8, 9, 10, 16, 18, 20, 32, 36, 40
1’b0, 1’b1
1’b0, 1’b1
40-bit hexadecimal number
40-bit hexadecimal number
1’b0, 1’b1
“rstreg”, “regce”
1’b0, 1’b1
2’b00, 2’b01, 2’b10, 2’b11
2’b00, 2’b01, 2’b10, 2’b11
2’b00, 2’b01, 2’b10, 2’b11
1’b0, 1’b1
2’b00, 2’b01, 2’b10, 2’b11
2’b00, 2’b01, 2’b10, 2’b11
2’b00, 2’b01, 2’b10, 2’b11
1’b0, 1’b1
1’b0, 1’b1
17-bit hexadecimal number
17-bit hexadecimal number
1’b0, 1’b1
1’b0, 1’b1
1’b0, 1’b1
1’b0, 1’b1